Consolidate and Scale Workloads with VMware vSAN Max on Lenovo ThinkSystem V3 Servers

Solution Brief

Home
Top
Published
25 Sep 2024
Form Number
LP2033
PDF size
12 pages, 559 KB

Abstract

The proliferation of technology, modern applications, cloud, artificial intelligence, and data-driven ecosystems necessitates on-premises infrastructure capable of handling high-performance and high-density workloads across data centers. Servers must incorporate software-defined solutions to construct robust storage systems and integrated software stacks for cloud, cloud-native technologies, and third-party software, enabling flexible and scalable architectures to accommodate any workload. This trend demands businesses to adopt faster servers and scalable storage to consolidate more workloads while achieving improved performance and lower latency.

VMware vSAN Max Disaggregated Storage

VMware vSAN Max is a distributed scale-out storage solution that leverages vSAN Express Storage Architecture (ESA) and provides petabyte-scale storage solution by increasing the number of nodes in the cluster. vSAN Max fully integrates with vCenter Server and supports serving storage for multiple vSphere compute clusters. It supports vSAN file services, iSCSI services, and data at rest encryption features.

 


Figure 1. vSAN Max Architecture

Lenovo ThinkSystem V3 Servers with VMware vSAN Max

Lenovo ThinkSystem vSAN Ready Nodes are the perfect choice to build VMware vSAN Max disaggregated storage in the data center to consolidate multiple workloads.  Lenovo ThinkSystem SR650 V3 systems are equipped with 4th Gen and 5th Gen Intel® Xeon® Scalable processors and supports VMware vSAN 8.  Lenovo and VMware are over 20 years of partnership and collaboration continues to strongly drive innovation and technical enablement for vSAN-based storage solutions. This includes validation, certification, configuration, and support for ThinkSystem and ThinkAgile VX systems.


Figure 2. ThinkSystem SR650 V3 workload suggestions

 

The following sections provide Login Enterprise (VDI) benchmark results done on vSAN ESA and vSAN Max configurations.  

VMware Horizon VDI Performance on vSAN ESA vs vSAN Max

The Login Enterprise VDI benchmark tool was used to perform testing for the” knowledge worker profile” using 3-node ThinkAgile VX630 V3 Certified Nodes to compare performance of vSAN ESA and vSAN Compute only cluster backed by vSAN Max. The knowledge worker profile generates 10-15 IOPS per user during steady state and the Login Enterprise VSImax metrics provides desktop density at 100% CPU utilization.  The testing was done with the following software versions and configuration.

  • Login Enterprise 5.12.3
  • VMware ESXi, 8.0.1-21495797, Instant Clone
  • VMware Horizon 8.9.0 build 21593375 v2303
  • Microsoft Windows 10 2H2 Enterprise Edition
  • Microsoft Office 365, Microsoft Edge
  • 2 VCPU + 4 GB Memory + 40 GB disk

 

Table 1: vSAN ESA and VSAN Max Cluster Hardware Configurations

vSAN ESA Cluster

vSAN Max Cluster

  • 3 x ThinkAgile VX630 V3 CN
  • Intel(R) Xeon(R) Platinum 8468 48C 2.1 GHz
  • 4 x ThinkSystem 2.5" U.3 7450 PRO 7.68TB Read Intensive NVMe PCIe 4.0 x4 HS SSD
  • 16 x ThinkSystem 64GB TruDDR5 4800MHz (2Rx4) 10x4 RDIMM
  • 1 x ThinkSystem Broadcom 57414 10/25GbE SFP28 2-port OCP Ethernet Adapter
  • RAID 5

vSAN Max Ready Nodes

  • 4 x ThinkSystem SR650 V3
  • INTEL(R) XEON(R) GOLD 6548Y+ 32C 2.5 GHz
  • 8 x ThinkSystem 2.5" U.3 7450 PRO 7.68TB Read Intensive NVMe PCIe 4.0 x4 HS SSD
  • 8 x ThinkSystem 64GB TruDDR5 4800MHz (2Rx4) 10x4 RDIMM
  • 1 x ThinkSystem Mellanox ConnectX-6 Lx 10/25GbE SFP28 2-Port PCIe Ethernet Adapter
  • RAID 5

vSAN Compute Only Nodes

  • 3 x ThinkAgile VX630 V3 CN
  • Intel(R) Xeon(R) Platinum 8468 48C 2.1 GHz
  • 16 x ThinkSystem 64GB TruDDR5 4800MHz (2Rx4) 10x4 RDIMM
  • 1 x ThinkSystem Broadcom 57414 10/25GbE SFP28 2-port OCP Ethernet Adapter 

10 GbE

10 GbE

RDMA Disabled

RDMA Disabled

VSIMax = 666, Total Desktops = 720

VSIMax = 891, Total Desktops = 930

 

Table 1 and Figure 3 show the user density of the knowledge worker profile and the test with vSAN Max storage resulted in ~33% improvement than vSAN ESA.

 


Figure 3. Login Enterprise Knowledge worker VSImax results on VMware vSAN ESA and vSAN Max

 


Figure 4. VMware vSAN Max host CPU utilization for Login Enterprise Knowledge worker 1000 user testing

Figure 4 shows the CPU utilization of the vSAN Max cluster node during the 930-user test and each node in the vSAN Max cluster utilized 15-20% CPU which can be mapped to vSAN IO processing. The vSAN ESA serves as both compute and storage on the same cluster and hence it provided lesser density than vSAN Max.

 


Figure 5. Login Enterprise Knowledge worker Login response time on VMware vSAN ESA and vSAN Max

Figure 5 shows the login performance and both vSAN ESA and vSAN Max provide comparable performance until VSImax is reached on the vSAN ESA cluster. The vSAN Max shows better login performance even after VSImax and it is because the storage system has enough compute to process IO.

 


Figure 6. Login Enterprise Knowledge worker Microsoft Outlook start time on VMware vSAN ESA and vSAN Max

Figure 6 shows Microsoft outlook start times and the performance looks comparable in both vSAN ESA and vSAN Max until vSAN compute nodes reached 75-85% CPU utilization. After this peak point the performance on vSAN ESA degrades and office applications start time increases as the hosts are serving both applications and vSAN IO.

 


Figure 7. Login Enterprise Knowledge worker Microsoft Edge page load time on VMware vSAN ESA and vSAN Max

Figure 7 shows browsing performance comparison of web pages with multimedia content and vSAN Max provides better response time than vSAN ESA until reaches VSImax. However, after peak point, the response time on vSAN Max increases drastically and it is due to increase in network latency between vSAN Compute and vSAN Max storage after compute is saturated.

VMware Cloud Foundation Support for vSAN Max

VMware Cloud Foundation (VCF) is a hybrid cloud platform designed to support virtual machines and container workloads. vSAN 8 Update 3 introduces support for storage-only clusters as principal storage in VCF 5.2. This allows VCF deployment to use vSAN disaggregated storage (vSAN Max) as their primary, centralized shared storage solution for all VCF workloads. vSAN Max provides maximum flexibility to scale compute and storage independently and manage lifecycle to achieve operational efficiency.

Lenovo and VMWare

With co-located engineering organizations and a history of technical collaboration, VMware and Lenovo consistently deliver innovative joint solutions for the data center. Lenovo’s leadership in reliability, customer satisfaction, and performance, combined with VMware’s leadership in software and cloud services, continues to deliver innovative data center solutions and lower TCO for our joint customers.

 

To learn more about Lenovo workload solutions on ThinkSystem SR650 V3 and ThinkAgile VX 630 V3 and VX 650 V3, contact your Lenovo Business Partner or visit: https://www.lenovo.com/systems/solutions

Related product families

Product families related to this document are the following:

Trademarks

Lenovo and the Lenovo logo are trademarks or registered trademarks of Lenovo in the United States, other countries, or both. A current list of Lenovo trademarks is available on the Web at https://www.lenovo.com/us/en/legal/copytrade/.

The following terms are trademarks of Lenovo in the United States, other countries, or both:
Lenovo®
ThinkAgile®
ThinkSystem®

The following terms are trademarks of other companies:

Intel® and Xeon® are trademarks of Intel Corporation or its subsidiaries.

Microsoft®, Microsoft Edge, Office 365®, Outlook®, and Windows® are trademarks of Microsoft Corporation in the United States, other countries, or both.

Other company, product, or service names may be trademarks or service marks of others.